Products / AGM

AGM.
Absorbed Glass Mat.

Sealed lead-acid VRLA, maintenance-free. Seven product series: start-stop, deep-cycle, general-purpose, front-terminal, high-rate, 2V cells and lead-carbon.

AGM — Absorbed Glass Mat

Lead-Acid VRLA

Lead-acid VRLA in its most versatile form. Seven series built around the chemistry and plate design for each duty: thin plates for cranking, thicker plates for cycling, lead-carbon plates for partial-state-of-charge operation. Every model listed below is live in the ATB range.

SSL Series — Start-Stop AGM

Start-Stop3× Cycle LifeHybrid-Cycle TestedSealed & Non-Spill

AGM for start-stop vehicles with idle-off, regenerative braking and frequent engine restarts. Lead-carbon plate technology delivers three times the cycle life of standard SLI, with strong charge acceptance and reliable cold cranking across repeated micro-hybrid cycles.

European LN1 to LN6 fitment. Tested to EN 50342 with over 400 endurance cycles and 8,000 micro-hybrid cycles.

ATB AGM SSL4 start-stop AGM battery
SSL series specifications
ModelVoltageGroup SizeC20 (Ah)CCA (A, EN)RC (min, 25A)Dimensions (mm)Weight
ATB AGM SSL112V140R/H450Ah570 A80 min207 × 175 × 19015.5 kg
ATB AGM SSL212V47/H560Ah660 A100 min242 × 175 × 19018.5 kg
ATB AGM SSL312V48/H670Ah720 A120 min278 × 175 × 19021 kg
ATB AGM SSL412V94R/H780Ah800 A140 min315 × 175 × 19024 kg
ATB AGM SSL512V49/H892Ah850 A160 min353 × 175 × 19026.5 kg
ATB AGM SSL612V95R/H9105Ah950 A190 min394 × 175 × 19030 kg
ATB SSL1 start-stop AGM batterySSL-1
ATB SSL2 start-stop AGM batterySSL-2
ATB SSL3 start-stop AGM batterySSL-3
ATB SSL4 start-stop AGM batterySSL-4
ATB SSL5 start-stop AGM batterySSL-5

Every SSL shares the same AGM lead-carbon plate technology. Match the size to your vehicle and get consistent start-stop performance across the lineup.

GP Series — General Purpose VRLA

Sealed VRLAFloat / StandbyUPS / AlarmWide Temp

Sealed AGM across the most common backup loads. From small solar home systems and security panels at 4.5 Ah to telecom cabinets, UPS strings and emergency lighting at 200 Ah.

Sealed VRLA. Maintenance-free. Multi-orientation install. Very low self-discharge and stable float voltage.

4.5 to 200 Ah across 6V and 12V. Design life five years under 20 Ah, ten years at 20 Ah and above at 25 °C in float duty. For front-terminal rack access, specify the FT series.

ATB AGM GP12-100 general purpose VRLA battery
GP series specifications
ModelVoltageC20 (Ah)C10 (Ah)C5 (Ah)Dimensions (mm)WeightTerminal
ATB AGM GP12-1.212V1.3Ah1.15Ah1.1Ah97 × 43 × 51.50.55 kgF1
ATB AGM GP12-2.312V2.3Ah2Ah1.95Ah97 × 43 × 510.55 kgF1
ATB AGM GP12-512V5Ah4.7Ah4.3Ah90 × 70 × 1001.56 kgF1
ATB AGM GP12-712V7Ah6.6Ah6Ah151 × 65 × 942.05 kgF1
ATB AGM GP12-912V9Ah8.5Ah7.7Ah151 × 65 × 942.43 kgF2
ATB AGM GP12-1212V12Ah11.4Ah10.2Ah151 × 98.5 × 953.45 kgF2
ATB AGM GP12-1812V18Ah16.2Ah14.5Ah151 × 98 × 953.45 kgM5
ATB AGM GP12-2612V26Ah24Ah22.5Ah175 × 165 × 1277.35 kgM5
ATB AGM GP12-3512V35Ah33Ah28.5Ah196 × 131 × 15510 kgM6
ATB AGM GP12-4012V42Ah40Ah34Ah197 × 166 × 17011.7 kgM6
ATB AGM GP12-5512V58Ah55Ah48Ah230 × 138 × 21016.7 kgM6
ATB AGM GP12-7012V68Ah65Ah55Ah348 × 167 × 17720 kgM6
ATB AGM GP12-10012V77Ah75Ah67.5Ah260 × 168 × 21121.7 kgM6
ATB AGM GP12-12012V120Ah111Ah96Ah332 × 175 × 21532 kgM8
ATB AGM GP12-15012V156Ah150Ah134Ah482 × 170 × 24044.5 kgM8
ATB AGM GP12-20012V210Ah200Ah186Ah522 × 240 × 21858 kgM8
ATB AGM GP12-20012V270Ah260Ah225Ah522 × 240 × 21858 kgM8
ATB AGM GP12-7 batteryGP12-7
ATB AGM GP12-18 batteryGP12-18
ATB AGM GP12-55 batteryGP12-55
ATB AGM GP12-100 batteryGP12-100
ATB AGM GP12-200 batteryGP12-200

DC Series — Deep-Cycle AGM

Deep CycleMaintenance-FreeAny OrientationSealed VRLA

Deep-cycle AGM for daily charge and discharge in off-grid solar, residential inverter banks, marine house banks and shift-cycle motive equipment. Plates and grid alloy specified for cycling duty rather than cranking.

Thick positive plates, high-tin grid alloy and high-density active paste tolerate 80% depth-of-discharge across thousands of cycles. Sealed VRLA, gas-recombinant, multi-orientation install. No topping up, no off-gassing.

Eighteen models across 6V, 8V and 12V from 35 to 260 Ah. Strong charge recovery from deep cycles. Low self-discharge for long storage between shifts. Operating range −20 to 55 °C.

ATB AGM DC12-210 deep-cycle battery
DC series specifications
ModelVoltageC20 (Ah)C5 (Ah)C3 (Ah)Dimensions (mm)WeightTerminal
ATB AGM DC6-2246V224Ah179Ah161Ah260 × 180 × 24830.5 kgM8
ATB AGM DC6-2506V250Ah200Ah180Ah260 × 182 × 26934.4 kgM8
ATB AGM DC6-3356V335Ah268Ah241Ah296 × 178 × 34547 kgDT
ATB AGM DC6-4006V400Ah320Ah288Ah296 × 178 × 40556 kgDT
ATB AGM DC8-2008V200Ah160Ah144Ah260 × 180 × 28037.4 kgM8
ATB AGM DC12-3512V35Ah28Ah25Ah195 × 131 × 1559.9 kgM6
ATB AGM DC12-5512V55Ah44Ah40Ah229 × 136 × 21016.4 kgM6
ATB AGM DC12-8512V85Ah68Ah61Ah260 × 168 × 21125 kgM8
ATB AGM DC12-10512V105Ah84Ah76Ah306 × 169 × 21628 kgM8
ATB AGM DC12-21012V210Ah168Ah151Ah522 × 240 × 21958 kgM8
ATB AGM DC12-26012V260Ah208Ah187Ah520 × 268 × 22073.5 kgLT
ATB AGM DC12-35 batteryDC12-35
ATB AGM DC12-85 batteryDC12-85
ATB AGM DC12-105 batteryDC12-105
ATB AGM DC12-210 batteryDC12-210
ATB AGM DC12-260 batteryDC12-260

Need to match a specific floor scrubber, scissor lift, MEWP or golf car to a DC Series battery? Use the equipment selector on the Motive application page →

HR Series — High-Rate VRLA

High-RateUPS & Data Center15-Minute RateSealed VRLA

High-rate sealed lead-acid AGM sized for short-duration, high-current UPS discharge. Purpose-built for large data centers, UPS/EPS and emergency power systems.

Performance rated in watts per cell at the 15-minute discharge rate to 1.67 volts per cell end-of-discharge. Pick the model by required power per string, not by amp-hour capacity.

Specialized grid plate design and alloy with low internal resistance. Thin-plate construction delivers high power density for runtime windows between 5 and 30 minutes.

ATB AGM HR12-150 high-rate UPS battery
HR series specifications
ModelVoltageW/cell @15minC20 (Ah)C5 (Ah)Dimensions (mm)WeightTerminal
ATB AGM HR12-3712V37W9Ah7.7Ah151 × 65 × 942.57 kgF1
ATB AGM HR12-9212V92W21.5Ah18.5Ah181 × 77 × 1676.3 kgM5
ATB AGM HR12-12012V120W30Ah26Ah165 × 125 × 1759 kgM5
ATB AGM HR12-15012V150W34Ah30Ah195 × 130 × 15511 kgM6
ATB AGM HR12-25012V250W57Ah53Ah229 × 138 × 21018 kgM6
ATB AGM HR12-30012V300W78Ah67Ah260 × 169 × 21124 kgM6
ATB AGM HR12-35012V350W94Ah80Ah306 × 169 × 21128.5 kgM6
ATB AGM HR12-42012V420W118Ah100Ah332 × 175 × 21532 kgM6
ATB AGM HR12-52012V520W143Ah134Ah341 × 173 × 28242.5 kgM6
ATB AGM HR12-37 batteryHR12-37
ATB AGM HR12-92 batteryHR12-92
ATB AGM HR12-150 batteryHR12-150
ATB AGM HR12-300 batteryHR12-300
ATB AGM HR12-520 batteryHR12-520

FT Series — Front Terminal

Front TerminalTelecom Rack10-Year FloatSealed VRLA

Front-terminal AGM for telecom cabinets, UPS and power network installs where front access matters. Ten year design life at 25 °C in float service.

Lead-calcium grid alloy with AGM separator. Front-terminal layout simplifies rack maintenance: install, connect and inspect from the cabinet face.

Sized for 19-inch and 23-inch telecom shelves and indoor UPS cabinets. 55 Ah to 200 Ah at the C10 rate, 12V.

ATB AGM FT12-100 front terminal long-life battery
FT series specifications
ModelVoltageC10 (Ah)C20 (Ah)C5 (Ah)Dimensions (mm)WeightTerminal
ATB AGM FT12-5512V55Ah60Ah50.8Ah277 × 106 × 22316 kgM6 front
ATB AGM FT12-7512V75Ah82Ah69.3Ah562 × 114 × 18827 kgM8 front
ATB AGM FT12-8012V80Ah87Ah73.9Ah390 × 105 × 25529.3 kgM8 front
ATB AGM FT12-10012V100Ah109Ah92.4Ah507 × 109 × 22332 kgM8 front
ATB AGM FT12-12512V125Ah136Ah115.5Ah550 × 105 × 31544.6 kgM8 front
ATB AGM FT12-15012V150Ah163Ah138.6Ah569 × 110 × 29047.5 kgM8 front
ATB AGM FT12-17012V170Ah185Ah157.1Ah561 × 125 × 31652.4 kgM8 front
ATB AGM FT12-18012V180Ah196Ah166.3Ah561 × 125 × 31655.5 kgM8 front
ATB AGM FT12-20012V200Ah217Ah184.8Ah561 × 125 × 31661.7 kgM8 front
ATB AGM FT12-55 batteryFT12-55
ATB AGM FT12-75 batteryFT12-75
ATB AGM FT12-100 batteryFT12-100
ATB AGM FT12-180 batteryFT12-180

LC Series — Lead-Carbon AGM

Solar Hybrid2,200+ CyclesPartial SoC DutySealed VRLA

Lead-carbon AGM for solar self-consumption and partial-state-of-charge duty — the operating window where standard AGM loses capacity within twelve to eighteen months.

Lead-carbon negative plates reduce sulfation under partial-state-of-charge operation, the duty common to solar self-consumption installs. Lower internal resistance and stronger charge acceptance than standard AGM under the same conditions. Over 2,200 cycles at 20% depth-of-discharge at 25 °C per manufacturer testing.

Sixteen models across 6V and 12V from 12 to 400 Ah at C10. Sealed VRLA, maintenance-free, multi-orientation install. Built for hybrid inverter systems, off-grid and hot-climate standby.

ATB AGM LC12-200 lead-carbon battery
LC series specifications
ModelVoltageC10 (Ah)C20 (Ah)C5 (Ah)Dimensions (mm)WeightTerminal
ATB LC12-20012V200Ah215Ah182.8Ah520 × 268 × 22065 kgM8
ATB LC12-23012V230Ah245Ah208.3Ah520 × 268 × 22072 kgM8
ATB LC12-200 batteryLC12-200
ATB LC12-230 batteryLC12-230

2V Series — High-Density VRLA Cells

10-Year FloatIndividual 2V CellsHigh CapacitySealed VRLA

2V VRLA cells for large UPS banks, utility standby, telecom central office, rail and power-plant DC systems. Capacities from 100 Ah to 3,000 Ah per cell.

Thick-plate design, low-weight electrolyte, sealed post construction. Low self-discharge for long storage between installs. Design life 10 years at 25 °C in float service.

ATB AGM 2V-500 stationary cell
2V series specifications
ModelVoltageC20 (Ah)C10 (Ah)C100 (Ah)Dimensions (mm)WeightTerminal
ATB AGM 2V-1002V110Ah100Ah121.77Ah171 × 72 × 2045.6 kgM8
ATB AGM 2V-2002V200Ah184Ah220Ah170 × 106 × 33212.5 kgM8
ATB AGM 2V-3002V300Ah276Ah330Ah172 × 151 × 31918 kgM8
ATB AGM 2V-6002V600Ah552Ah660Ah285 × 171 × 33036.5 kgM8
ATB AGM 2V-15002V2150Ah2000Ah2380.05Ah476 × 337 × 330111 kgM8
ATB AGM 2V-100 battery2V-100
ATB AGM 2V-500 battery2V-500
ATB AGM 2V-1000 battery2V-1000
ATB AGM 2V-1500 battery2V-1500
ATB AGM 2V-3000 battery2V-3000

All specifications nominal at 25°C. Weights and dimensions typical. Blank fields are pending vendor confirmation. LC capacities published at the C10 rate. Full datasheets and product drawings on request.

Need full datasheets or custom configurations?

Request Specifications